home *** CD-ROM | disk | FTP | other *** search
/ InfoMagic Standards 1994 January / InfoMagic Standards - January 1994.iso / ccitt / 1988 / troff / 6_4_01.tro < prev    next >
Text File  |  1991-12-13  |  49KB  |  1,715 lines

  1. .rs
  2. .\" Troff code generated by TPS Convert from ITU Original Files
  3. .\"                 Not Copyright ( c) 1991 
  4. .\"
  5. .\" Assumes tbl, eqn, MS macros, and lots of luck.
  6. .TA 1c 2c 3c 4c 5c 6c 7c 8c
  7. .ds CH
  8. .ds CF
  9. .EQ
  10. delim @@
  11. .EN
  12. .nr LL 40.5P
  13. .nr ll 40.5P
  14. .nr HM 3P
  15. .nr FM 6P
  16. .nr PO 4P
  17. .nr PD 9p
  18. .po 4P
  19.  
  20. .rs
  21. \v | 5i'
  22. .sp 1P
  23. .ce 1000
  24. \v'12P'
  25. \s12PART\ I
  26. \v'4P'
  27. .RT
  28. .ce 0
  29. .sp 1P
  30. .ce 1000
  31. \fBRecommendations Q.310 to Q.331\fR \v'2P'
  32. .EF '%     \ \ \ ^''
  33. .OF ''' \ \ \ ^    %'
  34. .ce 0
  35. .sp 1P
  36. .ce 1000
  37. \fBSPECIFICATIONS\ OF\ SIGNALLING\ SYSTEM\ R1\fR 
  38. .ce 0
  39. .sp 1P
  40. .LP
  41. .rs
  42. .sp 30P
  43. .LP
  44. .bp
  45. .LP
  46. \fBMONTAGE:\fR PAGE 2 = PAGE BLANCHE
  47. .sp 1P
  48. .RT
  49. .LP
  50. .bp
  51. .sp 1P
  52. .ce 1000
  53. \v'6P'
  54. \s10\fBSIGNALLING\ SYSTEM\ R1\fR \s9\v'3P'
  55. .RT
  56. .ce 0
  57. .sp 1P
  58. .ce 1000
  59. INTRODUCTION
  60. .EF '%    Fascicle\ VI.4\ \(em\ System\ R1''
  61. .OF '''Fascicle\ VI.4\ \(em\ System\ R1    %'
  62. .ce 0
  63. .sp 1P
  64. .ce 1000
  65. \fBPRINCIPLES\ OF\ SIGNALLING\ SYSTEM\ R1\fR 
  66. .ce 0
  67. .sp 1P
  68. .LP
  69. \fIGeneral\fR 
  70. .sp 1P
  71. .RT
  72. .PP
  73. The development of new exchanges, especially those utilizing
  74. stored programme control
  75. , has introduced new concepts in the division of functions between various 
  76. components of signalling and switching systems. To allow the maximum freedom 
  77. in incorporating new concepts which can contribute to the overall economy 
  78. and efficiency of the system, the requirements as covered in this specification 
  79. are for the combination of equipments necessary to 
  80. .PP
  81. provide a function. For example, the requirements for line signal receiving
  82. equipment as given here may be met by various subdivisions of functions
  83. between signal receiver, trunk relay sets and stored programme control.
  84. .PP
  85. System\ R1 may be applied for automatic and semi\(hyautomatic operation 
  86. of one\(hyway and both\(hyway circuits, within an international region 
  87. (world 
  88. numbering zone). When utilized in an 
  89. integrated world numbering zone
  90. (e.g.\ Zone\ 1) the numbering and routing plans and operating facilities 
  91. of that zone should apply. 
  92. .PP
  93. The system is applicable to all types of circuits (except\ TASI derived 
  94. circuits) 
  95. .FS
  96. Register signalling can be made compatible with TASI by providing a TASI 
  97. locking tone. 
  98. .FE
  99. meeting CCITT transmission standards, including
  100. satellite circuits.
  101. .PP
  102. The signalling equipment used in System\ R1 consists of two
  103. parts:
  104. .RT
  105. .LP
  106.     \fIa)\fR     line signalling for line or supervisory signals; and
  107. .LP
  108.     \fIb)\fR     register signalling for address signals.
  109. .LP
  110. .sp 2P
  111. .LP
  112. a)
  113.     \fILine signalling\fR 
  114. .sp 1P
  115. .RT
  116. .sp 1P
  117. .LP
  118. 1)
  119.     \fI2600 Hz signalling\fR 
  120. .sp 9p
  121. .RT
  122. .PP
  123. Continuous tone type in\(hyband line\(hysignalling
  124. is used for
  125. the link\(hyby\(hylink transmission of all supervisory signals except the
  126. ring\(hyforward (forward\(hytransfer) signal which is a spurt signal. A single
  127. frequency, 2600\ Hz, is used in each direction of the 4\(hywire transmission 
  128. path, the presence or absence of this frequency indicates a specific signal 
  129. dependent upon when it occurs in the signalling sequence and in certain 
  130. cases upon its 
  131. duration. When the circuit is idle, a low level signalling tone is continuously 
  132. present in both directions. 
  133. .RT
  134. .LP
  135. .sp 3
  136. .bp
  137. .sp 1P
  138. .LP
  139. 2)
  140.     \fIPCM signalling\fR 
  141. .sp 9p
  142. .RT
  143. .PP
  144. The 2600\ Hz line signalling described in 1) is not normally applied to 
  145. the speech paths of circuits working on PCM\ systems unless the PCM\ channels 
  146. are connected in cascade with analogue channels to form a circuit. The 
  147. signalling on PCM\ systems in the North American region is channel associated, 
  148. in\(hyslot, providing two signalling channels per speech channel, and utilizing 
  149. bit stealing of the eighth bit of each channel every sixth frame.
  150. .RT
  151. .sp 1P
  152. .LP
  153. b)
  154.     \fIRegister signalling\fR 
  155. .sp 9p
  156. .RT
  157. .PP
  158. See in Fascicle VI.2, Recommendation Q.151, Note to \(sc\ 3.1.1 for an 
  159. explanation of these terms. 
  160. .FE
  161. Link\(hyby\(hylink multifrequency (MF) in\(hyband pulse signalling
  162. is used for the transmission of address information. The signalling frequencies 
  163. are 700\ Hz to 1700\ Hz, in 200\ Hz steps, and combinations of two, and 
  164. two only, determine the signal. The address information is preceded by 
  165. a KP\ signal 
  166. .PP
  167. (start\(hyof\(hypulsing) and terminated by an ST\ signal (end\(hyof\(hypulsing). 
  168. Either \fIen\fR \fIbloc\fR , or \fIen bloc\fR overlap 
  169. , or overlap sending may apply.
  170. This register signalling arrangement is used extensively with other in\(hyband 
  171. and out\(hyband line signalling systems. 
  172. .PP
  173. Compandors may affect signalling, particularly short pulse compound
  174. register signals, due to pulse length distortion and the production of
  175. intermodulation frequencies. By virtue of the link\(hyby\(hylink signalling 
  176. and the adopted duration of register and line signal pulses, System\ R1 
  177. functions 
  178. correctly in the presence of compandors designed in accordance with CCITT
  179. recommendations.
  180. .RT
  181. .LP
  182. .rs
  183. .sp 28P
  184. .LP
  185. .bp
  186. .sp 1P
  187. .ce 1000
  188. \v'3P'
  189. SECTION\ 1
  190. .ce 0
  191. .sp 1P
  192. .ce 1000
  193. \fBDEFINITION\ AND\ FUNCTION\ OF\ SIGNALS\fR 
  194. .ce 0
  195. .sp 1P
  196. .sp 2P
  197. .LP
  198. \fBRecommendation\ Q.310\fR 
  199. .RT
  200. .sp 2P
  201. .sp 1P
  202. .ce 1000
  203. \fB1.\ DEFINITION\ AND\ FUNCTION\ OF\ SIGNALS\fR 
  204. .FS
  205. In this part the
  206. North American designation for line signals is used. The designation of the
  207. signal in System\ No.\ 5 which most nearly corresponds to a particular North
  208. American signal is shown in parentheses. There is not always exact
  209. correspondence in function, e.g.\ the ring\(hyforward signal can only be
  210. effective when a connection has been established through an incoming
  211. operator.
  212. .FE
  213. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.310''
  214. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.310    %'
  215. .ce 0
  216. .sp 1P
  217. .sp 2P
  218. .LP
  219. 1.1
  220.     \fBconnect (seizing) signal\fR (sent in the forward direction)
  221. .sp 1P
  222. .RT
  223. .PP
  224. This line signal is transmitted at the beginning of a call to
  225. initiate circuit operation at the incoming end of the circuit to busy the
  226. circuit and to seize equipment for switching the call.
  227. .RT
  228. .sp 1P
  229. .LP
  230. 1.2
  231.     \fBdelay\(hydialling signal\fR (sent in the backward direction)
  232. .sp 9p
  233. .RT
  234. .PP
  235. This line signal is transmitted by the incoming exchange following the 
  236. recognition of the connect (seizing) signal to verify receipt of the 
  237. connect (seizing) signal and to indicate that the incoming register equipment 
  238. is not yet attached or ready to receive address signals. 
  239. .RT
  240. .sp 1P
  241. .LP
  242. 1.3
  243.     \fBstart\(hydialling (proceed\(hyto\(hysend) signal\fR (sent in the backward
  244. direction)
  245. .sp 9p
  246. .RT
  247. .PP
  248. This line signal is sent from the incoming exchange subsequent to the sending 
  249. of a delay\(hydialling signal to indicate that the incoming register equipment 
  250. has been connected and is ready to receive address signals. 
  251. .RT
  252. .LP
  253. .sp 1P
  254. .LP
  255. 1.4
  256.     \fBKP (start\(hyof\(hypulsing) signal\fR (sent in the forward direction)
  257. .sp 9p
  258. .RT
  259. .PP
  260. This register signal is sent subsequent to the recognition of a
  261. start\(hydialling signal and is used to prepare the incoming multifrequency
  262. register for the receipt of subsequent interregister signals.
  263. .RT
  264. .sp 1P
  265. .LP
  266. 1.5
  267.     \fBaddress signal\fR (sent in the forward direction)
  268. .sp 9p
  269. .RT
  270. .PP
  271. This register signal is sent to indicate one decimal element of
  272. information (digit\ 1,\ 2,\ . |  | ,\ 9 or\ 0) about the called party's 
  273. number. For 
  274. each call a succession of address signals is sent.
  275. .RT
  276. .sp 1P
  277. .LP
  278. 1.6
  279.     \fBST (end\(hyof\(hypulsing) signal\fR (sent in the forward direction)
  280. .sp 9p
  281. .RT
  282. .PP
  283. This register signal is sent to indicate that there are no more
  284. address signals to follow. The signal is always sent in semi\(hyautomatic 
  285. as well as automatic working. 
  286. .RT
  287. .LP
  288. .sp 2
  289. .bp
  290. .sp 1P
  291. .LP
  292. Notes on the answer and hang\(hyup (clear\(hyback) signals.\ \(em\ See
  293. corresponding notes in Recommendation\ Q.120, \(sc\ 1.8, Volume\ VI\(hy2 of the
  294. \fIGreen Book\fR .
  295. .FE
  296. 1.7
  297.     \fBanswer signal\fR (sent in the backward direction)
  298. ,
  299. .FS
  300. See Recommendation Q.27 for the actions to be taken to assure that answer 
  301. signals, both national and international, are transmitted as quickly as 
  302. possible.
  303. .FE
  304. .sp 9p
  305. .RT
  306. .PP
  307. This line signal is sent to the outgoing exchange to indicate that the 
  308. called party has answered. 
  309. .PP
  310. In semi\(hyautomatic working, the signal has a supervisory function.
  311. .PP
  312. In automatic working, it is used:
  313. .RT
  314. .LP
  315.     \(em
  316.     to start metering the charge to the calling subscriber;
  317. .LP
  318.     \(em
  319.      to start the measurement of call duration for international accounting 
  320. purposes, if this is desired. 
  321. .LP
  322. .sp 1P
  323. .LP
  324. 1.8
  325.     \fBhang\(hyup (clear\(hyback) signal\fR (sent in the backward
  326. direction)
  327. .sp 9p
  328. .RT
  329. .PP
  330. This line signal is sent to the outgoing exchange to indicate that the 
  331. called party has cleared. In the semi\(hyautomatic service it performs 
  332. supervisory function.
  333. .PP
  334. In automatic working, arrangements are made to clear the connection, stop 
  335. the charging, and stop the measurement of call duration if within\ 10 to 
  336. 120\ seconds
  337. .FS
  338. In word numbering Zone\ 1, 13 to 32\ seconds is used.
  339. .FE
  340. after recognition of the hang\(hyup signal, the calling subscriber has 
  341. not cleared. 
  342. Clearing of the connection should preferably be controlled from the point 
  343. where the charging is carried out. 
  344. .RT
  345. .sp 1P
  346. .LP
  347. 1.9
  348.     \fBring\(hyforward (forward\(hytransfer) signal\fR (sent in the forward
  349. direction)
  350. .sp 9p
  351. .RT
  352. .PP
  353. This line signal is initiated by an operator to recall an operator at a 
  354. point further ahead in the connection. 
  355. .RT
  356. .sp 1P
  357. .LP
  358. 1.10
  359.     \fBdisconnect (clear\(hyforward) signal\fR (sent in the forward
  360. direction)
  361. .sp 9p
  362. .RT
  363. .LP
  364. .PP
  365. This line signal is sent in the forward direction at the end of a  call when:
  366. .RT
  367. .LP
  368.     \fIa)\fR     in semi\(hyautomatic working, the operator at the outgoing
  369. exchange withdraws the plug from the jack, or when an equivalent
  370. operation is performed;
  371. .LP
  372.      \fIb)\fR in automatic working, the calling party hangs up, or when the 
  373. time\(hyout period of\ 10 to 120\ seconds as discussed in \(sc\ 1.8\ above 
  374. occurs.
  375. .sp 1P
  376. .LP
  377. 1.11
  378.     \fIDiagrams showing signal sequence\fR 
  379. .sp 9p
  380. .RT
  381. .PP
  382. Typical sequences of signals in semi\(hyautomatic and automatic
  383. working are shown in Annex\ A to these Specifications of Signalling
  384. System\ R1.
  385. .RT
  386. .LP
  387. .rs
  388. .sp 13P
  389. .LP
  390. .bp
  391. .sp 1P
  392. .ce 1000
  393. \v'3P'
  394. SECTION\ 2
  395. .ce 0
  396. .sp 1P
  397. .ce 1000
  398. \fBLINE\ SIGNALLING\fR 
  399. .ce 0
  400. .sp 1P
  401. .sp 2P
  402. .LP
  403. \fBRecommendation\ Q.311\fR 
  404. .RT
  405. .sp 2P
  406. .LP
  407. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.311''
  408. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.311    %'
  409. .sp 1P
  410. .ce 1000
  411. \fB2.1\ 2600\ Hz\ LINE\ SIGNALLING\fR 
  412. .ce 0
  413. .sp 1P
  414. .PP
  415. The line\(hysignal coding arrangement is based on the application and removal 
  416. of a 
  417. single frequency tone (2600\ Hz)
  418. as shown in
  419. Table\ 1/Q.311.
  420. .sp 1P
  421. .RT
  422. .LP
  423. .rs
  424. .sp 33P
  425. .ad r
  426. \fBTable [1/Q.311], p.\fR 
  427. .sp 1P
  428. .RT
  429. .ad b
  430. .RT
  431. .LP
  432. .bp
  433. .PP
  434. By taking advantage of the fixed order of occurrence of specific
  435. signals, both tone\(hyon and tone\(hyoff signals are used to indicate more 
  436. than one signal condition. For example, in the backward direction tone\(hyon 
  437. is used to 
  438. indicate start\(hydialling (proceed\(hyto\(hysend), and terminating end 
  439. hang\(hyup 
  440. (clear\(hyback) signals without conflict. The equipment must retain memory 
  441. of the preceding signal states and the direction of signals in order to 
  442. differentiate between tone\(hyon and tone\(hyoff signals. 
  443. .sp 2P
  444. .LP
  445. \fBRecommendation\ Q.312\fR 
  446. .RT
  447. .sp 2P
  448. .sp 1P
  449. .ce 1000
  450. \fB2.2\ \fR \fB2600\ Hz\ LINE\ SIGNAL\ SENDER\fR 
  451. .FS
  452. See also
  453. Recommendation\ Q.112.
  454. .FE
  455. \fB\ (TRANSMITTER)\fR 
  456. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.312''
  457. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.312    %'
  458. .ce 0
  459. .sp 1P
  460. .sp 2P
  461. .LP
  462. 2.2.1
  463.     \fISignal frequency\fR 
  464. .sp 1P
  465. .RT
  466. .PP
  467. 2600\ \(+-\ 5\ Hz.
  468. .RT
  469. .sp 1P
  470. .LP
  471. 2.2.2
  472.     \fITransmitted signal level of tone\(hyon signals\fR 
  473. .sp 9p
  474. .RT
  475. .PP
  476. \(em8\ \(+-\ 1\ dBm0 for the duration of the signal or for a minimum of
  477. 300\ ms (whichever is shorter) and for a maximum of 550\ ms after which 
  478. the level of the signal shall be reduced to \(em20\ \(+-\ 1\ dBm0. 
  479. .RT
  480. .sp 1P
  481. .LP
  482. 2.2.3
  483.     \fITransmitted signal durations\fR 
  484. .sp 9p
  485. .RT
  486. .PP
  487. The transmitted signal durations are shown in Table\ 1/Q.311.
  488. .RT
  489. .sp 1P
  490. .LP
  491. 2.2.4
  492.     \fISignal frequency leak\fR 
  493. .sp 9p
  494. .RT
  495. .PP
  496. The level of signal frequency leak power transmitted to the line
  497. should not exceed \(em70\ dBm0, during the tone\(hyoff condition.
  498. .RT
  499. .LP
  500. .sp 1P
  501. .LP
  502. 2.2.5
  503.     \fIExtraneous frequency components\fR 
  504. .sp 9p
  505. .RT
  506. .PP
  507. The total power of extraneous frequency components accompanying a tone 
  508. signal should be at least 35\ dB below the fundamental signal power. 
  509. .RT
  510. .sp 1P
  511. .LP
  512. 2.2.6
  513.     \fITransmitting line split\fR 
  514. .sp 9p
  515. .RT
  516. .PP
  517. The following splitting arrangements are required when transmitting line 
  518. signals to prevent incorrect operation of the receiving equipment due to 
  519. transients caused by the opening or closing of direct current circuits 
  520. in the exchange at the transmitting end: 
  521. .RT
  522. .LP
  523.     \fIa)\fR     when a tone\(hyon signal is to be transmitted, the speech
  524. path from the exchange shall be split (disconnected), if not
  525. already split, within an interval from 20\ ms before, to
  526. 5\ ms
  527. .FS
  528. The 5\ ms may be relaxed to 15\ ms if tone is applied
  529. while tone is being received.
  530. .FE
  531. after tone is applied to
  532. the line, and remain split for a minimum of 350\ ms and a maximum
  533. of 750\ ms;
  534. .LP
  535.     \fIb)\fR     when a tone\(hyoff signal is to be transmitted, the speech
  536. path from the exchange shall be split (disconnected), if not
  537. already split, within an interval from 20\ ms before to 5\ ms
  538. after tone is removed from the line, and remain split for a
  539. minimum of 75\ ms and a maximum of 160\ ms after the tone is
  540. removed;
  541. .LP
  542.     \fIc)\fR     when the signalling equipment is receiving and sending
  543. tones simultaneously the split shall be maintained until:
  544. .LP
  545.     i)
  546.     the transmitted tone is terminated, in which case
  547. the split must be removed in the interval from\ 75 to
  548. 160\ ms after tone is removed [as in\ \fIb)\fR ]; or
  549. .LP
  550.     ii)
  551.      the incoming tone ceases, in which case the split must be removed in 
  552. the interval from\ 350 to 750\ ms after 
  553. tone ceases;
  554. .LP
  555. \fR     \fId)\fR     when the signalling equipment is sending tone, a split
  556. shall be introduced, if not already split, within 250\ ms of receipt of
  557. an incoming tone.
  558. .PP
  559. The above requirements given in \fIa)\fR , \fIb)\fR , \fIc)\fR and\ \fId)\fR 
  560. establish a transmitting path split at both ends of the circuit during 
  561. the idle condition. 
  562. .bp
  563. .LP
  564. .sp 2P
  565. .LP
  566. \fBRecommendation\ Q.313\fR 
  567. .RT
  568. .sp 2P
  569. .sp 1P
  570. .ce 1000
  571. \fB2.3\ 2600\ Hz\ LINE\ SIGNAL\ RECEIVING\ EQUIPMENT\fR 
  572. .FS
  573. See also
  574. Recommendation\ Q.112.
  575. .FE
  576. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.313''
  577. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.313    %'
  578. .ce 0
  579. .sp 1P
  580. .sp 2P
  581. .LP
  582. 2.3.1
  583.     \fIOperate limits (tone\(hyon signals)\fR 
  584. .sp 1P
  585. .RT
  586. .PP
  587. The receiving equipment shall operate on a received tone signal, in the 
  588. presence of the maximum noise expected on an international circuit, 
  589. \(em40\ dBm0 uniform spectral energy over the range of\ 300 to 3400\ Hz, 
  590. that meets the conditions listed below: 
  591. .RT
  592. .LP
  593.     \fIa)\fR     2600\ \(+-\ 15\ Hz;
  594. .LP
  595.      \fIb)\fR to ensure proper operation in the presence of noise, the signal 
  596. level of the initial portion of each tone\(hyon signal shall be 
  597. augmented by 12\ dB (see \(sc\ 2.2.2).
  598. .LP
  599. .PP
  600. As a result, the following requirement reflects both the augmented and 
  601. steady\(hystate signal levels. The absolute power level\ \fIN\fR of each 
  602. signal is within the limits (\(em27\ +\ \fIn\fR \ \(=\ \fIN\fR \ \(=\ \(em1\ 
  603. +\ \fIn\fR )\ dBm where\ \fIn\fR is the 
  604. relative power level at the input to the receiving equipment. The minimum
  605. absolute power level \fIN\fR \ =\ (\(em27\ +\ \fIn\fR ) gives a margin 
  606. of 7\ dB on the 
  607. steady\(hystate nominal absolute power level of the received signal at 
  608. the input to the receiving equipment. With augmentation the effective margin 
  609. is increased from\ 7 to 19\ dB. 
  610. .PP
  611. The maximum absolute power level\ \fIN\fR \ =\ (\(em1\ +\ \fIn\fR ) gives 
  612. a margin of 7\ dB on the augmented nominal absolute power level of the 
  613. received signal at the input to the receiving equipment. 
  614. .PP
  615. The above tolerances are to allow for variations at the sending end
  616. and variations in line transmission.
  617. .PP
  618. \fINote\fR \ \(em\ Since higher steady noise as well as impulsive noise 
  619. may be encountered on intra\(hyregional circuits especially over certain 
  620. compandored 
  621. carrier systems, the maximum expected noise within a region must be taken 
  622. into account in the design of equipment for that region. 
  623. .RT
  624. .sp 2P
  625. .LP
  626. 2.3.2
  627.     \fINon\(hyoperate limits\fR 
  628. .sp 1P
  629. .RT
  630. .PP
  631. 1)
  632. The receiving equipment shall neither operate on signals
  633. originating from subscriber stations (or other sources) if the total power 
  634. in the band from 800\ Hz to 2450\ Hz equals or exceeds the total power 
  635. present at 
  636. the same time in the band from 2450\ Hz to 2750\ Hz, as measured at the 
  637. station, nor degrade these signals. Allowances shall be made in the receiving 
  638. equipment design to accomodate expected deviations from these values due 
  639. to attenuation distortion and carrier frequency shift on the total transmission 
  640. path between the station and the receiving equipment. 
  641. .sp 9p
  642. .RT
  643. .PP
  644. 2)
  645. The receiving equipment shall not operate on any tone or signal whose absolute 
  646. power level at the point of connection of the receiving 
  647. equipment is (\(em17\ \(em20\ +\ \fIn\fR )\ dBm or less, \fIn\fR \ being 
  648. the relative power 
  649. level at this point.
  650. .sp 9p
  651. .RT
  652. .LP
  653. .sp 2P
  654. .LP
  655. 2.3.3
  656.     \fIRecognition of signals\fR 
  657. .sp 1P
  658. .RT
  659. .PP
  660. 1)
  661. System\ R1 must be protected against false signal recognition
  662. caused by:
  663. .sp 9p
  664. .RT
  665. .LP
  666.      \fIa)\fR signal simulation of tone\(hyon or tone\(hyoff signals by speech 
  667. or other signals; 
  668. .LP
  669.     \fIb)\fR     signal simulation of tone\(hyoff signals by momentary
  670. interruptions of the transmission path.
  671. .PP
  672. The method of providing this protection is left to each
  673. Administration concerned to allow for maximum flexibility in the implementation 
  674. of the signalling and switching system design. However, the overall system 
  675. requirements given in\ 2) and\ 3) below shall be met.
  676. .LP
  677. .sp 1
  678. .bp
  679. .PP
  680. 2)
  681. The following requirements for signal recognition are specified
  682. in terms of signal duration at the input to the signal receiving equipment 
  683. and further assumes that signal levels, frequency and accompanying noise 
  684. are within the limits specified in \(sc\ 2.3.1: 
  685. .sp 9p
  686. .RT
  687. .LP
  688. \fR 
  689.     \fIa)\fR     A 
  690. tone\(hyon signal
  691. lasting 30\ ms or less must be
  692. rejected; that is, it must not be recognized as a signal.
  693. .LP
  694.      \fIb)\fR A tone\(hyoff signal lasting 40\ ms or less must be rejected 
  695. if the previous tone\(hyon signal is 350\ ms or longer; that is, it 
  696. must not be recognized as a signal.
  697. .LP
  698.     \fIc)\fR     Subsequent to establishing the cross office path, a
  699. tone\(hyon ring\(hyforward (forward\(hytransfer) spurt signal
  700. lasting
  701. between\ 65 and 135\ ms must be recognized as a valid signal.
  702. .LP
  703.     \fId)\fR     A tone\(hyon forward signal lasting 300\ ms or longer
  704. must be recognized as a valid disconnect (clear\(hyforward) signal.
  705. Prior to attaching a register, a forward tone\(hyon signal lasting
  706. 30\ ms or longer may be recognized as a valid disconnect
  707. (clear\(hyforward) signal.
  708. .LP
  709.     \fIe)\fR     To protect against a momentary interruption in the
  710. transmission facility causing a continuous succession of false
  711. connect (seizing) and disconnect (clear\(hyforward) signals,
  712. .LP
  713. the incoming equipment should be arranged to delay responding to
  714. the second of two closely spaced connect (seizing) signals. The
  715. timed delay introduced should be started at the end of initial
  716. connect (seizing) signal or on recognition of the disconnect
  717. (clear\(hyforward) signal. The delay introduced should be a
  718. function of the round trip signalling time. For satellite
  719. circuits the recommended time is 1300\ \(+-\ 100\ ms. For terrestrial
  720. circuits the recommended time is 500\ \(+-\ 100\ ms. If the second
  721. connect (seizing) signal persists beyond this timed interval,
  722. the signal should be considered valid and a delay dialling
  723. signal returned.
  724. .LP
  725.     \fIf\fR \fI)\fR     Other tone\(hyon and 
  726. tone\(hyoff signals
  727. should  be recognized as valid signals, subsequent to the minimum limits
  728. imposed by\ \fIa)\fR and\ \fIb)\fR above, as soon as possible.
  729. .LP
  730. .PP
  731. \fINote\fR \ \(em\ Delays introduced by line signalling equipment should 
  732. be held to a minimum consistent with the requirements covered herein to 
  733. minimize signal transfer times. Minimizing the delay is especially important 
  734. in the case of the answer signal and in the case of satellite circuit operation. 
  735. In this 
  736. latter case, if a hang\(hyup (clear\(hyback) signal has not been sent prior to
  737. recognition of a disconnect (clear\(hyforward) signal, it is necessary that the
  738. idle tone\(hyon signal, sent by the incoming exchange in response to the
  739. disconnect signal, be recognized by the outgoing exchange prior to the 
  740. elapse of the guard timing specified in Recommendation\ Q.317, \(sc\ 2.7.1. 
  741. .PP
  742. 3)
  743. The following signal simulation rates shall not be
  744. exceeded.
  745. .sp 9p
  746. .RT
  747. .LP
  748. In the case when no answer signal is transmitted (non\(hycharged
  749. calls), the simulation rates specified in \(sc\(sc\ 3\ \fIa)\fR and\ 3\ 
  750. \fIb)\fR may, in some 
  751. existing designs, be somewhat in excess of the values quoted.
  752. .FE
  753. .LP
  754.     \fIa)\fR     On the average not more than one false recognition of a
  755. disconnect (clear\(hyforward) signal shall occur per\ 1500\ call hours 
  756. of speech, at the \fIminimum\fR disconnect recognition time, as selected 
  757. according to \(sc\ 2.3.3, 
  758. 2)\ \fIc)\fR and\ \fId)\fR . (In some older designs, this requirement may 
  759. not be met, but for these cases the call hours figure must not be less 
  760. than 500 
  761. call
  762. hours.)
  763. .LP
  764.     \fIb)\fR     On the average, not more than one false ring\(hyforward
  765. (forward\(hytransfer) signal shall occur per\ 70
  766. call hours of
  767. speech, at the \fIminimum\fR ring\(hyforward recognition time.
  768. .LP
  769.     \fIc)\fR     Speech or other electrical signals as audible\(hytone
  770. signals, with levels up to\ +10\ dBm0 shall not cause any false
  771. simulation of answer signals.
  772. .LP
  773.     \fId)\fR     The number and characteristics of false splits of the
  774. speech path caused by speech or other signals shall not cause a
  775. noticeable reduction in the transmission quality of the circuit.
  776. .LP
  777. .sp 1P
  778. .LP
  779. 2.3.4
  780.     \fIReceiving line split\fR 
  781. .sp 9p
  782. .RT
  783. .PP
  784. To prevent line signals of the signalling system from causing
  785. disturbances to signalling systems on subsequent circuits, the receiving
  786. transmission path to the connected exchange should be split when the signal
  787. frequency is received to ensure that no portion of any signal exceeding 
  788. 20\ ms duration may pass out of the circuit. The use of a band\(hystop 
  789. filter for 
  790. splitting is necessary since in the case of non\(hycharged calls a continuous
  791. signal tone persists in the return transmission path during conversation. 
  792. The level of signal leak current transmitted to the subsequent circuit 
  793. with the 
  794. band\(hystop filter inserted
  795. .bp
  796. .PP
  797. should be at least 35\ dB below the received  signal
  798. level. In addition, the band\(hystop filter must not introduce more than 5\ dB
  799. loss at frequencies 200\ Hz or more above or below the midband frequency nor
  800. more than 0.5\ dB loss at frequencies 400\ Hz or more above or below the 
  801. midband frequency. 
  802. .PP
  803. \fR The receiving line split must be maintained for the duration of the
  804. incoming tone signal, but must cease within 300\ ms of tone removal.
  805. .PP
  806. \fINote\fR \ \(em\ In some existing designs, the initial cut may be a physical 
  807. line disconnection but the filter must be inserted within 100\ ms of tone 
  808. reception.
  809. \v'2P'
  810. .RT
  811. .sp 2P
  812. .LP
  813. \fBRecommendation\ Q.314\fR 
  814. .RT
  815. .sp 2P
  816. .sp 1P
  817. .ce 1000
  818. \fB2.4\ \fR \fBPCM\ LINE\ SIGNALLING\fR 
  819. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.314''
  820. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.314    %'
  821. .ce 0
  822. .sp 1P
  823. .PP
  824. Individual channel line signalling is provided in the format of the CCITT 
  825. primary multiplex operating at 1544\ kbit/s (Recommendation\ G.733). Designated 
  826. signalling bits are marked\ 0 or\ 1 corresponding to tone\(hyon, 
  827. tone\(hyoff in the single frequency in\(hyband arrangement as shown in 
  828. Table\ 1/Q.311. As in the in\(hyband system, the same signalling state 
  829. is 
  830. used to indicate more than one signal by taking advantage of the fixed order
  831. of occurrence of specific signals. The equipment must retain memory of the
  832. preceding signal states and the direction of signals in order to differentiate 
  833. between like state\ 0 and state\ 1\ signals. 
  834. \v'2P'
  835. .sp 1P
  836. .RT
  837. .sp 2P
  838. .LP
  839. \fBRecommendation\ Q.315\fR 
  840. .RT
  841. .sp 2P
  842. .LP
  843. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.315''
  844. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.315    %'
  845. .sp 1P
  846. .ce 1000
  847. \fB2.5\ \fR \fBPCM\ LINE\ SIGNAL\ SENDER\fR \fB\ (TRANSMITTER)\fR 
  848. .ce 0
  849. .sp 1P
  850. .sp 2P
  851. .LP
  852. 2.5.1
  853.     \fISignalling format\fR 
  854. .sp 1P
  855. .RT
  856. .PP
  857. The primary multiplex format is shown in Figure\ 1/Q.315. Per
  858. channel, in\(hyslot signalling is accomplished by utilizing bit\ No.\ 8 
  859. in each time slot of the designated frames (6,\ 12,\ etc.) for signalling 
  860. purposes. Bit\ No.\ 8 of each time slot in the intervening frames (1\(hy5, 
  861. 7\(hy11,\ etc.) is used for 
  862. encoding speech. Two signalling channels per speech channel are provided 
  863. in the format. The multiframe alignment required for signalling purposes 
  864. is obtained by subdividing the 8\ kbit/s framing pulse stream into two 
  865. 4\ kbit/s streams, one for terminal framing and one for signalling framing 
  866. (S\(hybits). The relationship of the framing and multiframing signals to 
  867. the signalling bits is given in 
  868. Table\ 2/Q.315. Since only one line signalling channel is required for
  869. System\ R1, the same signalling information is sent over both signalling
  870. channels\ A and\ B.
  871. .RT
  872. .LP
  873. .sp 1P
  874. .LP
  875. 2.5.2
  876.     \fITransmitted signal duration\fR 
  877. .sp 9p
  878. .RT
  879. .PP
  880. The transmitted signal durations are given in Table\ 1/Q.311 of
  881. Recommendation\ Q.311.
  882. .RT
  883. .sp 1P
  884. .LP
  885. 2.5.3
  886.     \fITransmitting line split\fR 
  887. .sp 9p
  888. .RT
  889. .PP
  890. Since signalling is out\(hyband, no transmitting line split is
  891. required.
  892. .bp
  893. .RT
  894. .LP
  895. .rs
  896. .sp 22P
  897. .ad r
  898. \fBFIGURE 1/Q.315 p.2\fR 
  899. .sp 1P
  900. .RT
  901. .ad b
  902. .RT
  903. .LP
  904. .rs
  905. .sp 25P
  906. .ad r
  907. \fBTableau [2/Q.315] p.3\fR 
  908. .sp 1P
  909. .RT
  910. .ad b
  911. .RT
  912. .LP
  913. .bp
  914. .sp 2P
  915. .LP
  916. \fBRecommendation\ Q.316\fR 
  917. .RT
  918. .sp 2P
  919. .sp 1P
  920. .ce 1000
  921. \fB2.6\ \fR \fBPCM\ LINE\ SIGNAL\ RECEIVER\fR 
  922. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.316''
  923. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.316    %'
  924. .ce 0
  925. .sp 1P
  926. .sp 2P
  927. .LP
  928. 2.6.1
  929.     \fIRecognition of signals\fR 
  930. .sp 1P
  931. .RT
  932. .PP
  933. System R1 must be protected against false signal recognition caused by 
  934. signal simulation due to momentary loss of synchronization of the 
  935. PCM\ system. The method of providing this protection is left to each
  936. Administration concerned to allow for maximum flexibility in the implementation 
  937. of the signalling and switching system design. However, the overall system 
  938. requirements given below must be met.
  939. .RT
  940. .LP
  941.      \fIa)\fR A state\ 0 signal lasting 30\ ms or less must be rejected; that 
  942. is, it must not be recognized as a signal. 
  943. .LP
  944.      \fIb)\fR A state\ 1 signal lasting 40\ ms or less must be rejected if 
  945. the previous state\ 0 signal is 350\ ms or longer; that is, it 
  946. must not be recognized as a signal.
  947. .LP
  948.     \fIc)\fR     Subsequent to establishing the speech path, a state\ 0
  949. ring\(hyforward (forward\(hytransfer) signal lasting 65\(hy135\ ms must be
  950. recognized as a valid signal.
  951. .LP
  952.      \fId)\fR A state\ 0 forward signal lasting 300\ ms or longer must be 
  953. recognized as a valid disconnect (clear\(hyforward) signal. Prior to attaching 
  954. a register, a forward state\ 0 signal lasting 30\ ms or longer may be recognized 
  955. as a valid disconnect (clear\(hyforward) signal. 
  956. .LP
  957.      \fIe)\fR To protect against a momentary fault causing a continuous succession 
  958. of false connect (seizing) and disconnect (clear\(hyforward) signals, the 
  959. incoming equipment should be arranged to delay responding to the second 
  960. of two closely spaced connect (seizing) signals. The time delay introduced 
  961. .LP
  962. should be started at the end of the initial connect (seizing)
  963. signal or on recognition of the disconnect (clear\(hyforward)
  964. signal. The delay introduced should be a function of the round
  965. trip signalling time. For satellite circuits the recommended
  966. time is 1300\ \(+-\ 100\ ms. For terrestrial circuits the recommended
  967. time is 500\ \(+-\ 100\ ms. If the second connect (seizing) signal
  968. persists beyond this timed interval, the signal should be
  969. considered valid and a delay dialling signal returned.
  970. .LP
  971.     \fIf\fR \fI)\fR     Other state\ 0 and state\ 1 signals should be
  972. recognized as valid signals subsequent to the minimum limits imposed by\ 
  973. \fIa)\fR and\ \fIb)\fR above, as soon as possible. 
  974. .PP
  975. \fINote\fR \ \(em\ Delays introduced by line signalling equipment should 
  976. be held to a minimum consistent with the requirements covered herein to 
  977. minimize signal transfer times. Minimizing the delay is especially important 
  978. in the case of the answer signal and in the case of satellite circuit operation. 
  979. In this 
  980. latter case, if a hang\(hyup (clear\(hyback) signal has not been sent prior to
  981. .LP
  982. recognition of a disconnect (clear\(hyforward) signal, it is necessary that the
  983. idle state\ 0 signal, sent by the incoming exchange in response to the
  984. disconnect signal, be recognized by the outgoing exchange prior to the 
  985. elapse of the guard timing specified in Recommendation\ Q.317, \(sc\ 2.7.1. 
  986. .sp 1P
  987. .LP
  988. 2.6.2
  989.     \fIReceiving line split\fR 
  990. .sp 9p
  991. .RT
  992. .PP
  993. Since signalling is out\(hyband, no receiving line split is
  994. required.
  995. .RT
  996. .sp 1P
  997. .LP
  998. 2.6.3
  999.     \fIAction on receipt of an alarm\fR 
  1000. .sp 9p
  1001. .RT
  1002. .PP
  1003. When the PCM primary multiplex has detected a fault and given an
  1004. alarm (see Recommendation\ G.733,\ \(sc\ 3.2) appropriate action shall 
  1005. be taken to 
  1006. remove automatically the affected circuits from service, and to terminate 
  1007. calls in progress, i.e.\ stop charging, release interconnected circuits,\ 
  1008. etc. When the alarm has been cleared the affected circuits should be automatically 
  1009. restored to service. 
  1010. .RT
  1011. .LP
  1012. .sp 2P
  1013. .LP
  1014. \fBRecommendation\ Q.317\fR 
  1015. .RT
  1016. .sp 2P
  1017. .sp 1P
  1018. .ce 1000
  1019. \fB2.7\ FURTHER\ SPECIFICATION\ CLAUSES\ RELATIVE\ TO\ LINE\ SIGNALLING\fR 
  1020. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.317''
  1021. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.317    %'
  1022. .ce 0
  1023. .sp 1P
  1024. .PP
  1025. 2.7.1
  1026. Access to the outgoing circuits shall be denied (guarded)  
  1027. .sp 1P
  1028. .RT
  1029. .LP
  1030. for 750\ to 1250\ ms (1050\ ms to 1250\ ms for satellite circuits) after 
  1031. initiation of the disconnect (clear\(hyforward) signal to ensure sufficient 
  1032. time for the 
  1033. release of the equipment at the incoming exchange. [See also the Note
  1034. to \(sc\ 2.3.3,\ 2) of Recommendation\ Q.313 and to \(sc\ 2.6.1 of
  1035. Recommendation\ Q.316.]
  1036. .bp
  1037. .PP
  1038. 2.7.2
  1039. The disconnect (clear\(hyforward) signal may be sent at any time in the 
  1040. call sequence. 
  1041. .PP
  1042. 2.7.3
  1043. The release of the chain of circuits in an established connection is only 
  1044. initiated from the originating exchange or the charge\(hyrecording 
  1045. exchange.
  1046. .PP
  1047. 2.7.4
  1048. The start of metering the charge should be delayed by an
  1049. appropriate time after recording of the answer signal to prevent false 
  1050. charging resulting from possible false recognition of an invalid answer 
  1051. signal. 
  1052. .LP
  1053. .sp 2P
  1054. .LP
  1055. \fBRecommendation\ Q.318\fR 
  1056. .RT
  1057. .sp 2P
  1058. .sp 1P
  1059. .ce 1000
  1060. \fB2.8\ \fR \fBDOUBLE\ SEIZING\ WITH\ BOTH\(hyWAY\ OPERATION\fR 
  1061. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.318''
  1062. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.318    %'
  1063. .ce 0
  1064. .sp 1P
  1065. .sp 2P
  1066. .LP
  1067. 2.8.1
  1068.     \fIGeneral\fR 
  1069. .sp 1P
  1070. .RT
  1071. .PP
  1072. To minimize the probability of double seizing, the circuit
  1073. selection at the two ends of both\(hyway circuit groups should be such that, as
  1074. far as possible, double seizing can occur only when a single circuit of the
  1075. group remains free (e.g.\ by selection of circuits in opposite order at 
  1076. the two ends of the circuit group). 
  1077. .RT
  1078. .LP
  1079. .sp 1P
  1080. .LP
  1081. 2.8.2
  1082.     \fIUnguarded interval\fR 
  1083. .sp 9p
  1084. .RT
  1085. .PP
  1086. In general the unguarded interval is small, except in the case of satellite 
  1087. operation where the circuit propagation time is long. However, 
  1088. System\ R1 does provide a means of detecting double seizing.
  1089. .RT
  1090. .sp 1P
  1091. .LP
  1092. 2.8.3
  1093.     \fIDetection of double seizing\fR 
  1094. .sp 9p
  1095. .RT
  1096. .PP
  1097. In the event of double seizing, the incoming connect (seizing)
  1098. signal is recognized at each end as a delay\(hydialling signal. If a
  1099. start\(hydialling (proceed\(hyto\(hysend) signal is not received within 
  1100. the time\(hyout 
  1101. interval (e.g.\ 5\ seconds) double seizing is assumed.
  1102. .PP
  1103. In this event, either of the following arrangements may
  1104. apply:
  1105. .RT
  1106. .LP
  1107.     \fIa)\fR     an automatic repeat attempt to set up the call; or
  1108. .LP
  1109.      \fIb)\fR a recorder indication is given to the operator or to the calling 
  1110. subscriber and no automatic repeat attempt is made. 
  1111. .LP
  1112. .PP
  1113. With either method, means must be provided to ensure positive
  1114. release of the double seized circuit. To achieve the release it is recommended 
  1115. that the office which first assumes (based on timing) that dual seizure 
  1116. has 
  1117. occurred transmits a tone\(hyon (0\ state) signal followed by a tone\(hyoff 
  1118. (1\ state) signal before the final tone\(hyon (0\ state) signal (disconnect) 
  1119. is sent. The 
  1120. duration of initial tone\(hyon (0\ state) signal should be a minimum of 
  1121. 100\ ms and a maximum of 200\ ms. The tone\(hyoff (1\ state) signal should 
  1122. be recognized as an unexpected tone\(hyoff (1\ state) signal at the distant 
  1123. end, after which the action specified in \(sc\ 3.6.2,\ 1)\ \fIc)\fR of 
  1124. Recommendation\ Q.325 applies. 
  1125. .LP
  1126. .sp 2P
  1127. .LP
  1128. \fBRecommendation\ Q.319\fR 
  1129. .RT
  1130. .sp 2P
  1131. .sp 1P
  1132. .ce 1000
  1133. \fB2.9\ \fR \fBSPEED\ OF\ SWITCHING\ IN\ INTERNATIONAL\ EXCHANGES\fR 
  1134. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.319''
  1135. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.319    %'
  1136. .ce 0
  1137. .sp 1P
  1138. .PP
  1139. 2.9.1
  1140. It is recommended that the equipment in international
  1141. exchanges shall have a high switching speed so that the switching time 
  1142. may be as short as possible. 
  1143. .sp 1P
  1144. .RT
  1145. .PP
  1146. 2.9.2
  1147. At the outgoing, transit and incoming international exchanges,  
  1148. .LP
  1149. the seizing of the circuit and the setting up of the connection should take
  1150. place as soon as possible after receipt of the digits of the address that 
  1151. are necessary to determine the routing. 
  1152. .PP
  1153. 2.9.3
  1154. At international exchanges the delay\(hydialling signal should be
  1155. returned as soon as possible after recognition of the connect (seizing) 
  1156. signal. The start\(hydialling (proceed\(hyto\(hysend) signal should be 
  1157. returned as soon as 
  1158. possible but in any case, the return should be before the time\(hyout of the
  1159. outgoing register. [See \(sc\ 3.6.2,\ 1)\ \fIa)\fR and\ \fIb)\fR of Recommendation\ 
  1160. Q.325.] 
  1161. .LP
  1162. .bp
  1163. .sp 1P
  1164. .ce 1000
  1165. \v'3P'
  1166. SECTION\ 3
  1167. .ce 0
  1168. .sp 1P
  1169. .ce 1000
  1170. \fBREGISTER\ SIGNALLING\fR 
  1171. .FS
  1172. As used in this
  1173. Section the term register includes traditional registers in
  1174. electromechanical exchanges and also the equivalent receiving device,
  1175. memory and logic in stored program exchanges.
  1176. .FE
  1177. .ce 0
  1178. .sp 1P
  1179. .sp 2P
  1180. .LP
  1181. \fBRecommendation\ Q.320\fR 
  1182. .RT
  1183. .sp 2P
  1184. .sp 1P
  1185. .ce 1000
  1186. \fB3.1\ 
  1187. \fBSIGNAL\ CODE\ FOR\ REGISTER\ SIGNALLING\fR 
  1188. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.320''
  1189. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.320    %'
  1190. .ce 0
  1191. .sp 1P
  1192. .sp 2P
  1193. .LP
  1194. 3.1.1
  1195.     \fIGeneral\fR 
  1196. .sp 1P
  1197. .RT
  1198. .PP
  1199. 1)
  1200. Either semi\(hyautomatic working (with automatic machine or direct
  1201. operator access), or automatic working (with automatic machine access) may  
  1202. .sp 9p
  1203. .RT
  1204. .LP
  1205. be used for outgoing traffic. With automatic machine access the incoming
  1206. address signals are stored in a register until sufficient address information 
  1207. is received to route the call properly, at which time a free circuit may 
  1208. be 
  1209. selected and a connect (seizing) line signal sent. Subsequent to the
  1210. recognition of a delay\(hydialling line signal and a start\(hydialling
  1211. (proceed\(hyto\(hysend) line signal a KP (start\(hyof\(hypulsing) signal 
  1212. followed by the 
  1213. address and ST (end\(hyof\(hypulsing) signals are transmitted. The KP\ 
  1214. signal, which is nominally 100\ ms in duration, prepares the receiving 
  1215. equipment to accept 
  1216. subsequent register signals. The transmission of the KP\ signal should be
  1217. delayed by a minimum of 140\ ms, but not more than 300\ ms, after recognition 
  1218. of the start\(hydialling line signal. 
  1219. .PP
  1220. 2)
  1221. Link\(hyby\(hylink register signalling applies.
  1222. .PP
  1223. 3)
  1224. Register signalling is in a forward direction only and shall be
  1225. in accordance with the two\(hyout\(hyof\(hysix multifrequency code shown in
  1226. Table\ 3/Q.320. Three of the 15\ possible codes are unused in international
  1227. service and are available for special purposes.
  1228. .LP
  1229. .PP
  1230. 4)
  1231. The receiving equipment must furnish a two\(hyand\(hytwo only frequency 
  1232. check on each received signal to ensure its validity. 
  1233. .sp 2P
  1234. .LP
  1235. 3.1.2
  1236.     \fISending sequence of register signals\fR 
  1237. .sp 1P
  1238. .RT
  1239. .PP
  1240. 1)
  1241. The sending sequence of address signals conforms to the
  1242. sequence indicated in Recommendation\ Q.107. However, for traffic within an
  1243. integrated world numbering zone (e.g.\ Zone\ 1) the language or discriminating
  1244. digit and country codes may have no application and may not be sent. In 
  1245. Zone\ 1, the sequence of signals sent from the operator or subscriber is 
  1246. as 
  1247. follows:
  1248. \v'3p'
  1249. .sp 9p
  1250. .RT
  1251. .LP
  1252.     a)
  1253.     \fISemi\(hyautomatic working for calls to a subscriber within\fR 
  1254. \fIZone\ 1:\fR 
  1255. .LP
  1256.     i)
  1257.     KP;
  1258. .LP
  1259.     ii)
  1260.     national (significant) number of the called subscriber;
  1261. .LP
  1262.     iii)
  1263.     ST.
  1264. .LP
  1265. .sp 2
  1266. .bp
  1267. .LP
  1268.     b)
  1269.     \fISemi\(hyautomatic working for calls to operators within\fR \fIZone\ 1:\fR 
  1270. .LP
  1271.     i)
  1272.     KP;
  1273. .LP
  1274.     ii)
  1275.     special decimal numbers;
  1276. .FS
  1277. The special numbers used to
  1278. reach operators are by agreement between Administrations.
  1279. .FE
  1280. .LP
  1281.     iii)
  1282.     ST.
  1283. \v'3p'
  1284. .LP
  1285.     c)
  1286.     \fIAutomatic working for calls to a subscriber within\fR 
  1287. \fIZone\ 1:\fR 
  1288. .LP
  1289.     i)
  1290.     national (significant) number of the called subscriber.
  1291. .PP
  1292. 2)
  1293. The sending sequence of register signals shall conform to
  1294. Table\ 3/Q.320, noting the following:
  1295. .sp 9p
  1296. .RT
  1297. .LP
  1298.     \fIa)\fR     a KP (start\(hyof\(hypulsing) signal shall precede the sequence
  1299. of signals in all cases;
  1300. .LP
  1301.      \fIb)\fR the ST (end\(hyof\(hypulsing) signal shall follow the sequence 
  1302. of signals in all cases. 
  1303. .LP
  1304. .rs
  1305. .sp 17P
  1306. .ad r
  1307. \fBTABLE [3/Q.320], p.\fR 
  1308. .sp 1P
  1309. .RT
  1310. .ad b
  1311. .RT
  1312. .sp 2P
  1313. .LP
  1314. \fBRecommendation\ Q.321\fR 
  1315. .RT
  1316. .sp 2P
  1317. .ce 1000
  1318. \fB3.2\ \fR \fBEND\(hyOF\(hyPULSING\ CONDITIONS\fR \fB\ \(em\ REGISTER\fR 
  1319. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.321''
  1320. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.321    %'
  1321. .ce 0
  1322. .sp 1P
  1323. .ce 1000
  1324. \fBARRANGEMENTS\ CONCERNING\ ST\ SIGNAL\fR 
  1325. .ce 0
  1326. .sp 1P
  1327. .PP
  1328. 3.2.1
  1329. The register signalling arrangements shall provide for the
  1330. sending of an ST\ signal for both semi\(hyautomatic and automatic operation; 
  1331. the 
  1332. arrangements in the outgoing international register for recognizing the
  1333. ST (end\(hyof\(hypulsing) signal condition may vary as follows:
  1334. .sp 1P
  1335. .RT
  1336. .LP
  1337. .sp 1P
  1338. .LP
  1339. a)
  1340.     \fISemi\(hyautomatic operation\fR 
  1341. .sp 9p
  1342. .RT
  1343. .PP
  1344. The ST\ condition is determined by the receipt of the end\(hyof\(hypulsing 
  1345. signal initiated by the operator. 
  1346. .RT
  1347. .sp 1P
  1348. .LP
  1349. b)
  1350.     \fIAutomatic operation\fR \v'3p'
  1351. .sp 9p
  1352. .RT
  1353. .LP
  1354.     i)
  1355.     Where the ST\ condition is determined by the originating
  1356. national network, an ST\ signal is transmitted to the outgoing
  1357. international register. No further arrangements are
  1358. necessary in that register for this purpose.
  1359. .LP
  1360.     ii)
  1361.      Where the ST\ condition is not received from the originating national 
  1362. network, the outgoing international register will be 
  1363. required to determine the ST\ condition. (See for example the
  1364. requirements for System\ No.\ 5, Recommendation\ Q.152,
  1365. \fIGreen\ Book\fR .)
  1366. .bp
  1367. .LP
  1368. .sp 2P
  1369. .LP
  1370. \fBRecommendation\ Q.322\fR 
  1371. .RT
  1372. .sp 2P
  1373. .sp 1P
  1374. .ce 1000
  1375. \fB3.3\ \fR \fBMULTIFREQUENCY\ SIGNAL\ SENDER\fR 
  1376. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.322''
  1377. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.322    %'
  1378. .ce 0
  1379. .sp 1P
  1380. .PP
  1381. 3.3.1
  1382. Signalling frequencies 700, 900, 1100, 1300, 1500 and 1700\ Hz. A signal 
  1383. shall consist of a combination of any two of these six frequencies. 
  1384. The frequency variation shall not exceed \(+- | .5% of each nominal frequency.
  1385. .sp 1P
  1386. .RT
  1387. .LP
  1388. .PP
  1389. 3.3.2
  1390. Transmitted signal level \(em7\ \(+-\ 1\ dBm0 per frequency. The
  1391. difference in transmitted level between the two frequencies comprising 
  1392. a signal shall not exceed\ 0.5\ dB. 
  1393. .sp 9p
  1394. .RT
  1395. .PP
  1396. 3.3.3
  1397. Signal frequency leak and modulation products
  1398. . The
  1399. level
  1400. of the signal leak current transmitted to the line should be at least:
  1401. .sp 9p
  1402. .RT
  1403. .LP
  1404.     \fIa)\fR     50\ dB below the single frequency level when a
  1405. multifrequency signal is not being transmitted;
  1406. .LP
  1407.      \fIb)\fR 30\ dB below the transmitted signal level of either of the two 
  1408. frequencies when a multifrequency signal is being 
  1409. transmitted. The modulation products of a signal shall be at least 30\ 
  1410. dB below the transmitted level of either of the two frequencies comprising 
  1411. the 
  1412. signal.
  1413. .sp 1P
  1414. .LP
  1415. 3.3.4
  1416.     \fISignal durations\fR 
  1417. .sp 9p
  1418. .RT
  1419. .PP
  1420. KP signal: 100\ \(+-\ 10\ ms.
  1421. .PP
  1422. All other signals: 68\ \(+-\ 7\ ms.
  1423. .PP
  1424. Interval between all signals: 68\ \(+-\ 7\ ms.
  1425. .RT
  1426. .sp 1P
  1427. .LP
  1428. 3.3.5
  1429.     \fICompound signal tolerance\fR 
  1430. .sp 9p
  1431. .RT
  1432. .PP
  1433. The interval of time between the moments when the two frequencies comprising 
  1434. a signal are sent must not exceed 1\ ms. The interval of time between the 
  1435. moments when the two frequencies cease must not exceed 1\ ms. 
  1436. \v'2P'
  1437. .RT
  1438. .LP
  1439. .sp 2P
  1440. .LP
  1441. \fBRecommendation\ Q.323\fR 
  1442. .RT
  1443. .sp 2P
  1444. .sp 1P
  1445. .ce 1000
  1446. \fB3.4\ \fR \fBMULTIFREQUENCY\ SIGNAL\ RECEIVING\ EQUIPMENT\fR 
  1447. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.323''
  1448. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.323    %'
  1449. .ce 0
  1450. .sp 1P
  1451. .sp 2P
  1452. .LP
  1453. 3.4.1
  1454.     \fIOperate limits\fR 
  1455. .sp 1P
  1456. .RT
  1457. .PP
  1458. The signal receiving equipment must operate satisfactorily on any combination 
  1459. of two of the frequencies received as a single pulse or train of 
  1460. pulses in the presence of maximum expected noise on an international
  1461. circuit, \(em40\ dBm0 uniform spectral energy over the range of 300\ to 
  1462. 3400\ Hz, 
  1463. that meets the conditions listed below:
  1464. .RT
  1465. .LP
  1466.      \fIa)\fR each frequency of the received signal is within \(+- | .5% of 
  1467. the nominal signalling frequency; 
  1468. .LP
  1469.      \fIb)\fR the absolute power level\ \fIN\fR of each received frequency 
  1470. is within the limits 
  1471. .sp 1P
  1472. .ce 1000
  1473. (\(em14\ +\ \fIn\fR \ \(=\ \fIN\fR \ \(=\ +\ 0\ +\ \fIn\fR ) dBm
  1474. .ce 0
  1475. .sp 1P
  1476. .LP
  1477.      where \fIn\fR is the relative power level at the signal receiver input. 
  1478. Assuming a nominal circuit loss of 0\ dB these limits give 
  1479. a margin of \(+- | \ dB on the nominal absolute level of each
  1480. received signal. Considering that a single equipment may
  1481. serve circuits whose designed loss (nominal loss) is greater
  1482. than\ 0\ dB (e.g.,\ circuits that are not equipped with echo
  1483. suppressors) account must be taken of the highest circuit
  1484. loss in the design of the receiving equipment (e.g.,\ by
  1485. increasing must\(hyoperate sensitivity) to ensure that the
  1486. minimum margin is 7\ dB;
  1487. .bp
  1488. .LP
  1489.      \fIc)\fR the difference in level between the frequencies comprising a 
  1490. received signal is less than 6\ dB; 
  1491. .LP
  1492.      \fId)\fR the signal receiving equipment must accept signals meeting the 
  1493. following conditions: 
  1494. .LP
  1495.     i)
  1496.     signals within the limits specified in\ \fIa)\fR , \fIb)\fR ,
  1497. and\ \fIc)\fR  | bove in the presence of maximum expected noise and
  1498. subject to the maximum expected delay distortion;
  1499. .LP
  1500.     ii)
  1501.     the duration of each frequency comprising a signal is
  1502. 30\ ms or greater; and
  1503. .LP
  1504.     iii)
  1505.     the silent interval preceding the signal is 20\ ms or
  1506. greater.
  1507. .PP
  1508. The tolerances given in \fIa)\fR , \fIb)\fR , and\ \fIc)\fR  | re to allow for
  1509. variations at the sending end and in line transmission.
  1510. .PP
  1511. The test values indicated in\ \fId)\fR  | re less than the working values. 
  1512. The difference between the test value and the working values will allow 
  1513. for 
  1514. pulse distortion, variations in registration devices, etc.
  1515. .PP
  1516. \fINote\fR \ \(em\ Since higher steady noise as well as impulsive noise 
  1517. may be encountered on intraregional circuits, especially over certain compandored 
  1518. carrier systems, the maximum expected noise within a region must be taken 
  1519. into account in the design of equipment for that region. 
  1520. .RT
  1521. .sp 2P
  1522. .LP
  1523. 3.4.2
  1524.     \fINon\(hyoperate limits\fR 
  1525. .sp 1P
  1526. .RT
  1527. .PP
  1528. 1)
  1529. The receiving equipment shall not operate on any signal whose absolute 
  1530. power level at the point of the receiving equipment is 9\ dB or more 
  1531. below the must\(hyoperate sensitivity required to satisfy the conditions
  1532. established in \(sc\ 3.4.1\ \fIb)\fR .
  1533. .sp 9p
  1534. .RT
  1535. .PP
  1536. 2)
  1537. The receiving equipment shall release when the signal level
  1538. falls 1\ dB below the level established in \(sc\ 1) above.
  1539. .LP
  1540. .PP
  1541. 3)
  1542. Operation of the receiving equipment shall be delayed for a
  1543. minimum period necessary to guard against false operation due to spurious
  1544. signals generated internally on reception of any signal.
  1545. .PP
  1546. 4)
  1547. The receiving equipment should not operate on a pulse signal of
  1548. 10\ ms or less. This signal may be of a single frequency or two frequencies
  1549. received simultaneously. Likewise, after operation the equipment shall 
  1550. ignore short interruptions of the signal frequencies. 
  1551. .sp 1P
  1552. .LP
  1553. 3.4.3
  1554.     \fIInput impedance\fR 
  1555. .sp 9p
  1556. .RT
  1557. .PP
  1558. The value of the input impedance should be such that the return
  1559. loss over a frequency range of 500\ to 2700\ Hz against a 600\(hyohm non\(hyinductive 
  1560. resistor in series with a two\(hymicrofarad capacitor is greater than 
  1561. 27\ dB.
  1562. \v'2P'
  1563. .RT
  1564. .LP
  1565. .sp 2P
  1566. .LP
  1567. \fBRecommendation\ Q.324\fR 
  1568. .RT
  1569. .sp 2P
  1570. .sp 1P
  1571. .ce 1000
  1572. \fB3.5\ ANALYSIS\ OF\ ADDRESS\ INFORMATION\ FOR\ ROUTING\fR 
  1573. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.324''
  1574. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.324    %'
  1575. .ce 0
  1576. .sp 1P
  1577. .PP
  1578. In the application of System R1 to intraregional networks, the routing 
  1579. plan of that network shall apply. The routing plan is such that 
  1580. analysis is limited to a maximum of six digits.
  1581. .sp 1P
  1582. .RT
  1583. .PP
  1584. \fINote\fR \ \(em\ An ISC processing an incoming call on a circuit using
  1585. System\ R1, if encountering a barred routing or unallocated number condition,
  1586. should preferably send the special information tone toward the originating
  1587. subscriber.
  1588. .bp
  1589. .LP
  1590. .sp 2P
  1591. .LP
  1592. \fBRecommendation\ Q.325\fR 
  1593. .RT
  1594. .sp 2P
  1595. .sp 1P
  1596. .ce 1000
  1597. \fB3.6\ RELEASE\ OF\ REGISTERS\fR 
  1598. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.325''
  1599. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.325    %'
  1600. .ce 0
  1601. .sp 1P
  1602. .sp 2P
  1603. .LP
  1604. 3.6.1
  1605.     \fINormal release conditions\fR 
  1606. .sp 1P
  1607. .RT
  1608. .PP
  1609. 1)
  1610. An outgoing register shall be released when it has transmitted  the ST\ signal.
  1611. .sp 9p
  1612. .RT
  1613. .PP
  1614. 2)
  1615. An incoming register shall be released on the forward
  1616. transmission of the ST\ signal to the next exchange, or when all pertinent
  1617. information has been transferred to an outgoing register.
  1618. .sp 2P
  1619. .LP
  1620. 3.6.2
  1621.     \fIAbnormal release conditions\fR 
  1622. .sp 1P
  1623. .RT
  1624. .PP
  1625. 1)
  1626. An outgoing register shall release in any of the following
  1627. situations:
  1628. .sp 9p
  1629. .RT
  1630. .LP
  1631.     \fIa)\fR     on failure to recognize a delay\(hydialling signal within
  1632. 5\ seconds of circuit seizure unless a longer interval is preferred for
  1633. particular traffic conditions;
  1634. .LP
  1635.      \fIb)\fR on failure to recognize a start\(hydialling (proceed\(hyto\(hysend) 
  1636. signal within 5\ seconds of recognition of the delay\(hydialling signal 
  1637. unless a 
  1638. longer interval is preferred for particular traffic conditions;
  1639. .LP
  1640.     \fIc)\fR     on recognition of an unexpected tone\(hyoff (0\ state) line
  1641. signal subsequent to the recognition of a start\(hydialling (proceed\(hyto\(hysend) 
  1642. signal, but prior to completion of outpulsing. This signal sequence will 
  1643. occur in the event of double seizing and therefore a repeat attempt may 
  1644. be invoked 
  1645. and as a result the register may not be released prior to completion of the
  1646. second attempt. (See Recommendation\ Q.318.);
  1647. .LP
  1648.     \fId)\fR     on exceeding overall register timing of 240\ seconds.
  1649. .PP
  1650. 2)
  1651. An incoming register shall release in any of the following
  1652. situations:
  1653. .sp 9p
  1654. .RT
  1655. .LP
  1656.     \fIa)\fR     on failure to receive the KP\ signal within\ 10 to
  1657. 20\ seconds of register seizure;
  1658. .LP
  1659.     \fIb)\fR     on failure to receive the 1st through 3rd\ digits within
  1660. 10\ to 20\ seconds of receipt of the KP signal;
  1661. .LP
  1662.     \fIc)\fR     on failure to receive the 4th through 6th digits within
  1663. 10\ to 20\ seconds of the registration of the 3rd\ digit;
  1664. .LP
  1665.      \fId)\fR on failure to receive the remaining digits and ST\ signal within 
  1666. 10\ to 20\ seconds of registration of the 6th\ digit; 
  1667. .LP
  1668.     \fIe)\fR     on error detection such as receipt of one or more than
  1669. two frequencies in a pulse;
  1670. .LP
  1671.      \fIf\fR \fI)\fR on failure to gain access to associated switching equipment 
  1672. within appropriate intervals of time. 
  1673. .PP
  1674. The timing intervals given in\ 1) and\ 2) above are representative values 
  1675. but need not necessarily apply to all types of switching systems or all 
  1676. traffic loads. 
  1677. .PP
  1678. An abnormal release of an outgoing register on failure to receive a
  1679. delay\(hydialling signal as discussed in 1)\ \fIa)\fR above, shall result 
  1680. in the 
  1681. circuit being locked out which maintains the tone\(hyoff (1\ state) condition
  1682. toward the distant end. The maintenance personnel should be alerted.
  1683. .PP
  1684. Abnormal releases should result in the return of an audible re\(hyorder 
  1685. (congestion) tone toward the originating end. If this condition (re\(hyorder) 
  1686. persists for more than 1\ to 2\ minutes, maintenance personnel should be
  1687. alerted.
  1688. .RT
  1689. .sp 2P
  1690. .LP
  1691. \fBRecommendation\ Q.326\fR 
  1692. .RT
  1693. .sp 2P
  1694. .sp 1P
  1695. .ce 1000
  1696. \fB3.7\ SWITCHING\ TO\ THE\ SPEECH\ POSITION\fR 
  1697. .EF '%    Fascicle\ VI.4\ \(em\ Rec.\ Q.326''
  1698. .OF '''Fascicle\ VI.4\ \(em\ Rec.\ Q.326    %'
  1699. .ce 0
  1700. .sp 1P
  1701. .PP
  1702. At all exchanges, the circuit shall be switched to the speech position 
  1703. when the registers (incoming or outgoing) are released. 
  1704. .sp 1P
  1705. .RT
  1706. .LP
  1707. .bp
  1708. .LP
  1709. \fBMontage:\ \fR PAGE 20 = PAGE BLANCHE
  1710. .sp 1P
  1711. .RT